• Quality system certified to ISO 13485 for medical devices, alongside ISO 9001:2015.
  • Legends sit under the film, so there is no raised ink to wear or trap dirt.
  • Every unit is function-tested before shipment, and a certificate of conformance ships with each lot.

Requirements

What does a medical keypad have to withstand?

Three needs come up again and again in the medical inquiries we receive: repeated disinfection, operation in gloves, and liquid on the panel.

RequirementWhat it does to a switchHow the build answers it
Daily wipe-downsAlcohol, quaternary ammonium and dilute bleach haze or soften some films and inksHard-coated polyester overlay, legends printed on the back of the film
Gloved operationSoft or quiet keys go unnoticed through nitrileMetal snap domes for a clear tactile and audible click
Spills and fluidsLiquid that reaches a silver trace corrodes itContinuous overlay, sealer film, bonded perimeter and a closed tail exit
High-touch surfacesHospitals ask for antimicrobial frontsAntimicrobial-treated overlay with an ISO 22196 test report on request

Sealing details are on the sealed membrane switch page, and dome choice on the tactile membrane switch page.

Overlay

Which overlay suits a medical device?

Matte hard-coated polyester is the usual choice. It takes repeated flexing and cleaning chemicals, and a matte face hides fingerprints, which is why matte was specified in 151 of 187 finish choices across our project records.

Polycarbonate is used where print clarity or a crisp display window matters more. On one diagnostic analyser, a 0.25mm polycarbonate overlay was bonded with 3M 9495LE so the adhesive could form an unbroken seal around the display window.

Settle the window tint early: a clear window shows the digits at all times, a grey tinted one hides them until they light. More on films and finishes in made-to-order overlay options.

Common medical builds

  • Patient and nurse-call keypads
  • Front panels for diagnostic and laboratory analysers
  • Infusion and dosing equipment controls
  • Handheld instruments with a flexible PCB tail

Documentation

What documents come with a medical membrane switch?

Medical device makers need records they can put in their own file. These are part of a normal order.

Before

First article report

First parts from production tooling measured against your drawing, with actual values recorded.

Sample approval

Every unit

Functional test

Each switch is tested on the line before shipment; results go with the lot.

Functional testing

Every lot

CoC and material records

A certificate of conformance per lot, with RoHS and REACH compliance documents for the materials used.

Pre-shipment inspection

Hospital beds

What does a hospital bed keypad need?

An electric hospital bed usually carries two keypads: a hand pendant for the patient and a larger panel on the footboard or side rail for the caregiver. Both are membrane keypads, but they are specified differently because different people press them.

KeypadWho presses itWhat to specify
Patient pendantA patient lying down, often weak or unsteadyLarge raised keys with a clear click, simple pictograms, a sealed edge against spills
Caregiver panelNurses and carers, often wearing glovesEvery bed function, lockout keys to disable the patient pendant, status LEDs, gloved-hand key force
BothCleaned between patientsOverlay and inks tested against your disinfectants, and a sealed perimeter

A bed maker that asks for quotes usually wants the same short list first: materials and overlay finishes, circuit options, minimum order, the RFQ steps, prototype and production lead times, and the ISO 13485 certificate. We make the keypad; the bed itself is certified by the bed maker against its medical device standards, and we supply the material and test records that file needs. Key feel for gloved hands is covered on the tactile membrane switch page.

Cleaning

How do you prove a medical keypad survives hospital cleaning?

We rub-test the printed legends on an abrasion tester before samples ship. Medical drawings now spell the test out: 500g of force on the printing surface, 50 strokes with 99.7% isopropyl alcohol, then ethanol, then distilled water. The pass result is no erasure.

TestAs written on the drawingPass result
IPA rubbingAbrasion tester, 500g force on the printing surface, 99.7% isopropyl alcohol, 50 timesNo erasure
Ethanol rubbingSame tester and force, 99.7% ethanol, 50 timesNo erasure
Distilled water rubbingSame tester and force, distilled water, 50 timesNo erasure

The rub test rarely comes alone. A five-key drawing for a patient monitoring device that reached us this month listed it next to lettering "resistant to the hospital grade cleaning agents", a keypad that must "prevent any liquid ingress into the product in install condition", 100,000 cycles per key, an actuation force of 275g ±70g, contact resistance under 150 ohms per key and ESD to IEC 61000-4-2.

Legends printed on the back of the overlay film sit under the film, so the cloth rubs the film rather than the ink. Anything printed on the top surface, such as a texture or a window border, has to pass the test on its own. The electrical lines on such a drawing are explained on the membrane switch electrical specifications page.

FAQ

Medical membrane switch questions

Are you certified to ISO 13485?

Yes. Our quality system is certified to ISO 13485 for medical devices, as well as ISO 9001:2015.

Which cleaning agents can a medical membrane switch take?

Hard-coated polyester overlays are used with alcohol, quaternary ammonium and dilute bleach wipes. Send the exact products and cleaning routine with your inquiry, and the overlay and seal are chosen and checked on samples against them.

Which rub test do medical keypads have to pass?

The usual drawing line is 50 strokes on an abrasion tester at 500g force with 99.7% isopropyl alcohol, repeated with ethanol and distilled water, with no erasure allowed. We run that test on samples and report the result. If your drawing names other cleaning agents, send them and they are tested the same way.

Can a membrane switch be autoclaved?

Steam sterilisation is far harsher than wiping and needs a dedicated material stack. Tell us the cycle temperature, pressure and count, and we build and test samples to that cycle before committing to production.

Can keys be operated with gloves?

Yes. Metal domes give a click that carries through nitrile and latex gloves, and embossed keys help fingers find them without looking.

Tell us about your medical device

Send the layout, the cleaning agents it will meet and any sealing or antimicrobial requirement. The quote comes back within 48 hours.